35

LUBRICATION

Lubricate the following parts every three months

to insure smooth operation and reduce wear.

MIXER BRIDGE

HOUSING

There are two grease

nipples on the mixer
bridge swivel housing
which are accessed
by removing the front
and back covers on
the 18" console.

Side View of 18" Console

TRUNNION

HOUSING,
WORM SCREW
AND TILT GEAR

These parts are

accessed through the
front cover on the 18"
console.

Trunnion and Tilt Mechanism Drawing

Apply grease to gear
teeth. Check for
excessive play and
adjust with adjusting
screw located on top
of cross bar

.

KETTLE

TRUNNIONS

Accessed via the top
covers on the 10" and
18" consoles. Each
has two grease
nipples.

Kettle Trunnion Drawing

DISASSEMBLY OF SWITCH

ASSEMBLY

1. Place slotted

screwdriver
between contactor
cartridge and
cartridge mounting
block as shown in
Fig.1.

2. Twist screwdriver
to free cartridge.

3. Place screwdriver
under tab in the back
of the cartridge
mounting block as
shown in Fig. 3.

4. Twist screwdriver
to remove block from
the rotary switch.

3. Unscrew locking
ring to remove rotary
switch.

Switch Assembly

Contactor
cartridges

Cartridge
mounting
block

Locking
ring

Rotary switch

Fig. 1

Fig. 3

Fig. 2

Fig. 4

Trunnion Housing

Grease Nipple

Adjusting

Screw

Worm
Screw and
Tilt
Gear

Cross

Bar

Grease
Nipples

Front
Cover

Back
Cover

Advertising