Cleveland Range MKDL-125-CC User Manual

Page 9

Advertising
background image

6

OPTIONAL CONTROLS

Some units may not have the following items to test

13. Meter

Complete this test using markings on mixer arm or a measuring strip if there are no
markings on the unit. Test the meter at the following values up to capacity (Should be
approx. ±1/4"). During this test check that the (interrupt) switch stops the water flow
and the (continue/reset) when switched to "continue" resumes the flow without resetting
the meter.

GALLONS

LITERS

5

20

20

80

40

160

80

320

100

400

When the (continue/reset) switch is turned to "reset" the displayed quantity on the
meter should be erased and the count begins at zero.

For the following test fill the kettle 3/4 full of water. Have the mixer rotating with the speed
control setting at three to five.

14. Heating Manual

(Active/Bypass) switch in "Bypass" position. (Heat/Off/Cool) switch in "Heat"
position. Open manual steam valve, steam enters kettle and condensate escapes
from steam trap.

For units equipped with water cooling -
1

1..// Automatic drain opens and discharges water from jacket,
2

2..// Automatic drain closes when steam starts exiting,
3

3..// Condensate drain opens and discharges hot water.

Close manual steam valve and you should hear steam entering kettle slow to a
stop.

15. Cooling Manual

Turn (Heat/Off/Cool) switch to "Off". Open manual steam valve. Turn
(Heat/Off/Cool) switch to "Cool". Cooling water enters kettle from large console and
exits from side console.

16. Heating Automatic

(Heat/Off/Cool) switch in "Off" position. Open manual steam valve. Follow
operating instructions on label to set the temperature to 180°F/ 90°C. Turn
(Active/Bypass) switch to "Active", you should hear steam entering kettle and
condensate should escape steam trap.

For units equipped with water cooling -
1

1..// Automatic drain opens and discharges water from jacket,
2

2..// Automatic drain closes when steam starts exiting,
3

3..// Condensate drain opens and discharges hot water.

17 Chart Recorder

a

a)) Seal chart recorder on the inside all around to the panel with silicone.
b

b)) Seal pipe penetration where cables enters panel from console with silicone all
around.

Advertising