Carrier 50ZH024-060 User Manual

Installation, start-up and service instructions

Advertising
background image

Installation, Start-Up and

Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . 1

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

RECEIVING AND INSTALLATION

. . . . . . . . . . . . 5-11

Step 1 — Check Equipment

. . . . . . . . . . . . . . . . . . . 5

• IDENTIFY UNIT
• INSPECT SHIPMENT

Step 2 — Provide Unit Support

. . . . . . . . . . . . . . . 5

• SLAB MOUNT

Step 3 — Provide Clearances

. . . . . . . . . . . . . . . . . 5

Step 4 — Place Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . 5

Step 5 — Select and Install Ductwork

. . . . . . . . . 5

Step 6 — Provide for Condensate Disposal

. . . . 7

Step 7 — Install Electrical Connections

. . . . . . . 7

• HIGH-VOLTAGE CONNECTIONS
• ROUTING POWER LEADS INTO UNIT
• CONNECTING GROUND LEAD TO UNIT GROUND
• ROUTING CONTROL POWER WIRES
• ACCESSORY ELECTRIC HEAT WIRING
• SPECIAL PROCEDURES FOR 208-V

OPERATION

PRE-START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-15

Check for Refrigerant Leaks

. . . . . . . . . . . . . . . . . 12

Start-Up Cooling Section and

Make Adjustments

. . . . . . . . . . . . . . . . . . . . . . . . 12

Refrigerant Charge

. . . . . . . . . . . . . . . . . . . . . . . . . . 12

MAINTENANCE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-17

Air Filter

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Unit Top Removal (Outdoor Coil Side)

. . . . . . . . 16

Indoor Blower and Motor

. . . . . . . . . . . . . . . . . . . . 16

Outdoor Coil, Indoor Coil,

and Condensate Drain Pan

. . . . . . . . . . . . . . . . 16

Outdoor Fan

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Electrical Controls and Wiring

. . . . . . . . . . . . . . . 16

Refrigerant Circuit

. . . . . . . . . . . . . . . . . . . . . . . . . . 17

Indoor Airflow

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Metering Devices

. . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Liquid Line Strainers

. . . . . . . . . . . . . . . . . . . . . . . . 17

TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . 18,19

START-UP CHECKLIST

. . . . . . . . . . . . . . . . . . . . . CL-1

NOTE TO INSTALLER

Before the installation, READ THESE INSTRUCTIONS

CAREFULLY AND COMPLETELY. Also, make sure the
Owner’s Manual and Service Instructions are left with the
unit after installation.

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment

can be hazardous due to system pressure and electrical com-
ponents. Only trained and qualified workers should install,
repair, or service air-conditioning equipment.

Untrained workers can perform basic maintenance func-

tions of cleaning coils and filters. All other operations should
be performed by trained service people. When working on
air-conditioning equipment, pay attention to precautions in
the literature, tags and labels attached to the unit, and other
safety precautions that may apply.

Follow all safety codes. Wear safety glasses and work gloves.

Use quenching cloth for unbrazing operations. Have fire ex-
tinguisher available for all brazing operations.

Before performing service or maintenance operations on
system, turn off main power to unit. Turn off accessory
heater power switch if applicable. Electrical shock can
cause personal injury.

GENERAL

50ZH cooling units are fully self-contained and designed

for outdoor installation. See Fig. 1. As shown in Fig. 2-4,
units are shipped in a horizontal-discharge configuration for
installation on a ground-level slab.

Fig. 1 — Unit 50ZH (Size 030 Shown)

50ZH024-060

Single-Package Heat Pump Units

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

5a 5a

PC 111

Catalog No. 535-007

Printed in U.S.A.

Form 50ZH-2SI

Pg 1

9-96

Replaces: 50ZH-1SI

Advertising