WARNING: IT IS STRONGLY RECOMMENDED THAT YOU PERIODICALLY CHECK ALL BOLTS FOR PROPER TORQUE!!!

Mount Installation:

NOTE: The K13-510 clamp is designed to function as a 'single-piece' clamp when installed properly, meaning that one end of
the clamp 'contacts' the arm first while the other end has a 'gap' for the final clamping pressure.

CAUTION: Due to the clamping design and bolt thread engagement, maintain a torque of 1.5 N-m MAX or bolt failure
will result.


1.

Remove the 2x M3 x 8mm bolts from the upper clamp half (K13-512)

2.

Install the mount onto the right side (driveside) of the stem on the 22.2mm time trial handlebar.

3.

Install the upper clamp half (K13-512) back onto the lower clamp half (K13-511).

4.

Install, but do not tighten, the 2x M3 x 8mm bolts back into the clamp assembly.

5.

Tighten the INNER CLAMP BOLT (the bolt closest to the insert (K13-503)) fully to 1.25 N-m.

6.

Position the mount to your desired position and 'lightly' tighten the OUTER CLAMP BOLT to hold that position.

7.

Carefully torque the OUTER CLAMP BOLT to 1.25 N-m.

***IF you wish to adjust the 'tension' of lever action on the TT Mount, please proceed to " Lever Action Adjustment".