8

P 22

AUX 1 maximum value (default: 100)

Range

-27 to +100

- Sets the level for the Auxiliary output when the MIDI controller source is at its maximum.
A value of 10 is approximately 1 volt – so 100 is approx. 10 volts and –27 is approx. −2.7 volts.
Note that minimum can be set above maximum so that the controller works backwards.


P 23

AUX 1 reset value (default: 0)


Range

0 to 127

- Sets the level the Auxiliary output will reset to when the MODULAR SOLO is powered on or when it
receives a controller reset MIDI command or a new setup is loaded from memory. This is equivalent to
a MIDI message of this value being received, so it will be influenced by min and max settings above.


P 24

Key scale to AUX 1(default: 0)

Range

0 to 127

- Sets the amount of key scaling which is applied to the Aux output (for opening the filter up as you play
notes further up the keyboard. Most synths do this internally even when connected to a CV converter –
however not all do, a particular exception being the Sequential Pro-One. This feature enables key-
scale to filter, even when not otherwise available on the synth.


P 25

LFO to AUX 1 controller (default: 17)

- Sets which Controller will control the LFO depth applied to the AUX1 output.
The following can be selected:
Off

[oFF]

Pitch bend

[Pbd]

Velocity

[VEL]

Aftertouch

[AFt]

MIDI controllers

0 to 119


P 26

LFO to AUX 1 minimum value (default: 0)


Range

0 to 127

- Sets the level for LFO to AUX modulation when the MIDI controller source is at its minimum.
Note that minimum can be set above maximum so that the controller works backwards.


P 27

LFO to AUX 1 maximum value (default: 64)

Range

0 to 127

- Sets the level for LFO to AUX modulation when the MIDI controller source is at its maximum.
Note that minimum can be set above maximum so that the controller works backwards.


P 28

LFO to AUX 1 reset value (default: 0)


Range

0 to 127

- Sets the level the LFO to AUX1 modulation will reset to when the MODULAR SOLO is powered on or
when it receives a controller reset MIDI command or a new setup is loaded from memory. This is
equivalent to a MIDI message of this value being received, so it will be influenced by min and max
settings above.