To speed up editing - if you are holding the INC button and want to go faster, press the DEC button
too, this will step about twice as fast, similarly if you are holding the DEC button you can press INC to
go faster.

When you have edited parameters to your own specification, go to the “STORE to Mem#x” menu
option, where, by selecting which of seven locations you wish to use and pressing ENTER you can save
your set-up. The most recently LOADed or STOREd setup will be loaded next time you power-up. You
can get to the LOAD / STORE location quickl;y by holding the SEL button in for a couple of seconds.

PARAMETERS

THE FOLLOWING PARAMETERS ARE THE SAME FOR BOTH OF THE CV

CHANNELS, A, B (where x is the channel)

CV x SYNTH CHANNEL x

(1 to 16, defaults: A=1 B=2)


- sets the MIDI receive channel for Pro-2000 mkII analogue channel.

CV x NOTE PRIORITY

(low/high/newest, default: newest)


- sets the note priority.
If set to "Lowest" then the new note played takes precedence if it is lower than the preceding note.
If set to "Highest" then the new note played takes precedence if it is higher than the preceding note.
If set to "Newest" then the newest played note played takes precedence regardless.

CV x TRIGGER MODE

(Single/Multiple, default: Multiple)


- sets the whether the envelope on your synth will be retriggered when a new, overlapping note is
played. If set to "Single," then the Gate output will stay on, or the trigger (if selected) will not re-trigger
when a new note is played, if you are playing in a legato fashion, with notes overlapping.
If set to "Multiple," then the Gate (or S-Trig) output will re-Gate each time a new note is played, re-
triggering your synth`s envelope generators, regardless of your playing style.

CV x TRANSPOSE

(-24 to +24 semitones, default: 0)


- allows you to Transpose the incoming MIDI notes in semitone steps. You can adjust this in real-time,
allowing you to hear the changes you make to Transpose, without having to re-play a key.

CV x PITCHBEND

(0 to 24 semitones, default: 2)


- sets the maximum range the pitchbend will bend the CV output.


CV x PORTAMENTO TYPE (

fixed rate or fixed time, default: fixed rate)


- sets how the next parameter affects the portamento.
Fixed rate: the time taken to glide between notes depends on the amount of notes in the glide range.
The glide time between semitones is constant.

Fixed time: the time taken to glide between notes is the same no matter how far apart the notes are.