Keri Systems EP1502 User Manual

Ep1502 intelligent controller, General, Ep1502 hardware

Advertising
background image

Mercury Security Corporation © 2011

EP1502

DOC 10107-0031

REV 1.05

Page 1

www.mercury-security.com

2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.

EP1502 Intelligent Controller

with Two Reader Interface

Installation and Specifications:

1. General

The EP1502 intelligent controller provides decision making, event reporting, and database storage for the
Mercury hardware platform. Two reader interfaces provide control for two doors.

It communicates with the host via on-board 10-BaseT/100Base-TX Ethernet port. Alternatively, port 1
(RS-232) can be used for host communication.

Two physical barriers can be controlled with the EP1502. Each reader port can accommodate a read-
head that utilizes Wiegand, magnetic stripe, or 2-wire RS-485 electrical signaling standards, one or two
wire LED controls, and buzzer control (one wire LED mode only). Four Form-C relay outputs may be
used for strike control or alarm signaling. The relay contacts are rated at 5 A @ 30 Vdc, dry contact
configuration. Eight inputs are provided for monitoring the door contacts, exit push buttons and alarm
contacts. The EP1502 requires 12-24 Vdc for power. It is recommended that the EP1502 be mounted
.25" minimum above any conductive surface.

2. EP1502 Hardware:

J4

J3

1

2

3

TMP

FLT

R1

R2

+

1

3

2

4

J8

RE

SET

S2

BT1

3V BR/CR2330

J1

5V

3.3V

2

3

4

1

S1

VBAT

IN1

K

1
K

2
K

3
K

4

K2

K1

K3

K4

IN2

IN3

IN4

IN5

IN6

IN7

IN8

8V

J6

J2

J5

J7

PASS

12V

GND

DAT

D0

TB8

R

EADE

R

1

BZR

VO

G

N

D

FLT

GND

TMP

GND

VIN

TB1

LED

D1

CLK

R

EADE

R

2

D1

LED

VO

BZR

GND

CLK

D0

DAT

TB9

NO

OUT 1 C

NC

NO

OUT 2 C

NC

NC

OUT 4 C

NC

NO

NO

OUT 3 C

TB

10

TB

11

RXD

CTS

GND

RTS

TXD

TB2

TB

3

TR+

GND

TR-

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

TB4

TB5
TB6

TB7

.25 [6.35]

5.50 [139.70]

.25 [6.35]

6.00 [152.40]

.50 [12.70]

2.00 [50.80]

3.00 [76.20]

2.00 [50.80]

.50 [12.70]

8.00 [203.20]

Ø.156 [3.96]
8 PLACES

RESET SWITCH

BATTERY: BR/CR2330

REPLACE ANNUALLY

-

STATUS LED's

DIP SWITCHES

RELAY

STATUS

LED's

INPUT

STATUS

LED's

ETHERNET

SHIELD

Advertising