Keri Systems EP1502 User Manual

Page 7

Advertising
background image

Mercury Security Corporation © 2011

EP1502

DOC 10107-0031

REV 1.05

Page 7

11. Specifications:

The interface is for use in low voltage, Class 2 Circuits only.

The installation of this device must comply with all local fire and electrical codes.

Primary Power:

12-24 Vdc±10%, 500 mA maximum (reader current not included)
12 Vdc @ 250 mA (plus reader current) nominal
24 Vdc @ 150 mA (plus reader current) nominal

Memory and Clock
Backup Battery:

3 Volt Lithium, type BR2325, BR2330 or CR2330

Host Communication:

Ethernet: 10BaseT/100Base-TX, and RS-232; 9,600 to 115,200 bps,
asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.

SIO Communication

2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex,
1 start bit, 8 data bits, and 1 stop bit.

Inputs:

Two dedicated for tamper and UPS fault monitoring.
Eight for door position monitoring, request to exit or alarm contacts.

Relays:

Four each: Form-C, 5 A @ 30 Vdc, resistive.

Reader Interface:

Reader Power:

12 Vdc±10% regulated, current limited to 150 mA for each reader.

(jumper selectable) or

12 to 24 Vdc±10% (input voltage passed through) current limited to 150 mA
for each reader.

Data Inputs:

TTL compatible inputs, mag stripe and Wiegand standards supported.
Maximum cable length: 500 ft (152 m).

RS-485 Mode:

9,600 to 38,400 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1
stop bit. Maximum cable length: 2000 ft (609.6 m).

LED Output:

TTL levels, high>3 V, Low<0.5 V, 5 mA source/sink maximum.

Buzzer Output:

TTL levels, high>3 V, Low<0.5 V, Low=Active, 5 mA source/sink maximum.

Cable requirements:

Power:

1 twisted pair, 18 AWG.

Ethernet:

CAT-5, minimum.

RS-485:

(I/O Device Port): 24 AWG, 4,000 ft (1,219 m) maximum, twisted pair(s) with an overall shield.

(Reader Port):

24 AWG, 2,000 ft (609.6 m) maximum, twisted pair(s) with an overall shield.

RS-232:

24 AWG, 25 ft (7.6 m) maximum.

Alarm Input:

1 twisted pair, 30 ohms maximum, typically 22 AWG @ 1000 ft (304.8 m).

Environmental:

Temperature:

0 to 70 °C, operating, -55 to +85 °C, storage

Humidity:

10 to 95% RHNC

Mechanical:

Dimension:

8 in (203.2 mm) W x 6 in (152.4 mm) L x 1 in (25 mm) H

Weight:

9 oz (255 g) nominal, board only