P/N 01803-004 Rev. D

3.2

Wiegand Compatible Reader Connection

NOTE: The wire colors called out in Figure 3 are industry standard wire colors. However, some
manufacturers may not follow these industry standard designations. Before installation, please refer
to the Wiegand device’s manual to see if the device’s wire colors follow the industry standard. If not,
then match the wire’s purpose to the callouts in Figure 3 before installation.

Figure 3: Wiegand Compatible Reader Connection

3.3

Reader Responses to Access Control Events

4.0

Input Connections

4.1

Normally Closed Input Device - Door Status Switch

Figure 4: Door Status Switch Input Device

4.2

Normally Open Input Device - Request To Exit (RTE)

Figure 5: Request To Exit Input Device

4.3

Normally Open Input Device - Auxiliary Request To Exit A-
Door

Figure 6: Auxiliary Request To Exit A-Door Input Device

4.4

Normally Open Input Device - Global Unlock

Figure 7: Global Unlock Input Device

5.0

Output Connections

5.1

Lock Relay – Fail-Safe

In the event of a power failure at a door set up with a fail-safe lock relay, the door will automatically
unlock allowing people to exit through that door.

Figure 8: Fail-Safe Lock Relay

5.2

Lock Relay – Fail-Secure

In the event of a power failure at a door set up with a fail-secure lock relay, the door will
automatically lock and not allow entrance, but will continue to allow people to exit through that door.

Figure 9: Fail-Secure Lock Relay

5.3

Alarm Out

Figure 10: Alarm Out Relay

1530 Old Oakland Road, Suite 100
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Event

Reader’s LED Status

Reader’s Beeper

Status

waiting for an event

displays a steady Amber LED

silent

access granted

displays a Green LED until the door is

closed or the door unlock time is reached

one long Beep

access denied

flashes a Red LED

one short Beep

door alarm

flashing Red LED for the duration of the

alarm condition

pulsating Beep for the duration

of the alarm condition

door RTE

displays a Green LED until the door is

opened or the door unlock time is reached

one long Beep