0 communication, 1 between entraguard titanium unit and tenants, Section 05 - communication – Keri Systems EntraGuard Titanium Quick Start User Manual

Page 11: Entraguard, Titanium telephone entry controller, Quick start guide

Advertising
background image

EntraGuard

®

Titanium Telephone Entry Controller

Quick Start Guide

Page 11 of 26

P/N: 01962-001 Rev. D

5.0

Communication

The communication section handles three different, but related, topics:

Communication between EntraGuard Titanium controller and tenants

Communication between the master EntraGuard Titanium controller and the host computer for programming

Communication between networked EntraGuard Titanium/PXL-500/510 controllers

NOTE: Keri Systems recommends performing a bench test on each unit prior to installation to rule out any phone line
problems.

5.1

Between EntraGuard Titanium Unit and Tenants

The telephone communication is done via a copper phone line to TB-15. Connect the TIP line to either Pin 1 or Pin 2 then
connect the Ring line to the other Pin (see Figure 12).

Figure 12: TB-15 Phone Line Wiring Connection

There are three ways of connecting the phone line for communication between the EntraGuard Titanium unit and the
tenants.

5.1.1

Single Phone Line for a Single EntraGuard Titanium Unit

For a single EntraGuard Titanium unit, connect the phone line to TB-15 on the EntraGuard Titanium board (see Figure
2 on page 2).

5.1.2

Individual Phone Lines for each EntraGuard Titanium Unit on a Network

The set up for individual phone lines for each EntraGuard unit is the same as for a single phone line for a single
EntraGuard Titanium controller. Each phone line is connected to TB-15 on each EntraGuard Titanium board.

5.1.3

Shared Phone Line for Multiple EntraGuard Titanium Units on a Network

A single phone line may be shared for communication between multiple EntraGuard Titanium units and tenants. The
phone line is plugged into TB-15 on the master EntraGuard Titanium unit with the phone line then going out of the TB-15
phone plug to the next unit’s TB-15 and so on to all the networked EntraGuard units (see Figure 13 on page 12).

NOTE: Sharing a phone line for multiple EntraGuard units is limited to a maximum of 6 units per phone line.

Advertising