Instruction Manual

FH

FH_SO-BA-e-1217

3

-

1 x Press: Data Transfer [rS232] to PC
(PC) or to the printer (Print) or (in version U
5.1) to the test stand (stand)


- PC: Pressing SET once: Saves the Settings
- PRINT: Pressing SET twice: sending data to the printer
- STAND: Pressing SET three times: sending a signal to
the Test Stand to stop its movement (in version U 5.1)

Back Light:

PEAK:

Three functions
-

Track mode (continuous measurement)

-

Peak mode (capture of maximum values)

-

Auto-Peak mode, same as Peak-mode, only
without the „Min limit peak save“ function

MEMORY:

Saves the peak values to calculate the average
value (please see section

“Memory mode”


DELETE Function


Deletes stored peak values (only in

„Memory

mode

“ active)



PRINT:

Sends the stored peak values to a PC or Printer
(plea

se see section „Data Output”)


High / Low limit function


LEDs to display OK / NOT OK Tests

Lower than lower limit

OK

OK

Higher than higher limit


This function allows efficient testing of OK / NOT OK
measurements of similar or identical testing objects.
A lower and an upper limit value can be defined. The
instrument compares the individual measuring results with
these limit values and shows the OK or NOT OK result by
green or red light diode and by sound.

To set these limit values, please see the SET Menu in
section „Operating keys“.

Measurement (Track Modus)

Display (1) shows the continuous force in a defined
direction (6)

To zero the display, press:




Peak-Hold Function (Peak Mode)


Please press:


Auto-Peak-Hold-Function(Auto-Peak Mode)


Please press:


Min. limit peak save


This function allows to eliminate unwanted „Pre-Peak
values“ that are lower than the main peak value (Fp). The
“Min limit peak save” value (Fo) takes care, that these
“Pre-Peak values” are not saved.

The „Min limit peak save“ function is only possible in
Peak-Mode.

To set this Min limit value, please see the SET Menu in
section „Operating keys“.

Memory mode and average value (from up to 10 peak

values)

Saving peak values in the instrument

Activating the „AUTO PEAK Function“ by PEAK key


Deactivating the „Average Function“ by MEMORY
key


 Now, all peak values are stored automatically in the

instrument

HoldT

rS232