TROUBLESHOOTING

The Lippert Hydro-Sync Slideout System is only one of four interrelated
slideout room system components. These four components are as
follows: chassis, slideout room, coach and Lippert Hydro-Sync Slideout
System
. Each one needs to function correctly with the others or
misalignment problems will occur.

Every coach has it’s own personality and what may work to fix one coach
may not work on another even if the symptoms appear to be the same.

When something restricts room travel, system performances will be
unpredictable. It is very important that slide rails, inner and outer, be free
of contamination and allowed to travel freely the full distance or
“STROKE.” Ice or mud buildup during travel is an example of some
types of contamination that may occur.

When beginning to troubleshoot the system, make sure the battery is
fully charged, there are no visible signs of external damage to the
actuator, motor or rails and that the motor is wired properly and all
connections are secure.

You can adjust room extension by modifying the position of the
adjustment coupler.

During troubleshooting, remember, by changing, altering or adjusting one
thing, it may affect something else. Be sure any changes do not create a
new problem.

Additional information on the Lippert Hydro-Sync Slideout System
by calling 866-524-7821 and asking for technical assistance.