Lippert Components In Wall Slide-Out System User Manual

Page 7

Advertising
background image

Rev: 11.21.2014

Page 7

IN-WALL™ Slide-out Owner's Manual

Fig. 9

Harness

Motor

Obstructions

Check outside the RV for possible obstructions: tree, post, car, etc. Check inside the RV for any obstructions:

luggage, furniture, open cabinets, etc. Also, check for smaller objects that may be wedged under the floor or in the

sides of unit. Remove obstructions before proceeding.

Checking Fuses

The Lippert IN-WALL™ Slide-out requires a minimum of a 30-amp fuse. Check the 12-volt fuse box for blown fuses,

and replace any if necessary. Consult the RV manufacturer's documentation for the location of the 12-volt fuse

box, and the location of the IN-WALL™ Slide-out controller’s fuse. If the fuse blows immediately upon replacement,

there is a problem with the wiring to the IN-WALL Slide-out controller. Have qualified service personnel check and

repair.

Motors and Harnesses

1. Check for proper connections between the motors and harnesses (Fig. 9).

2. Visually inspect the exposed harnesses to ensure they are not pinched or damaged.
NOTE: Ribs on motor connector line up with notch inside of male connector on wiring harness. Color codes

on wires also match (black to black, red to red, etc.).

Resynchronizing the Slide-out Motors

3. Fully extend the slide room using the switch. Keep the switch engaged until the motors shut down on

their own.

4. Retract the room 1-2 inches.
5. Repeat steps 1 and 2 until both motors shut down at the same time. In many cases, two or three

repetitions are necessary to re-sync the system.

6. Fully extend and then retract the room. Again, always let the motors shut down on their own before

releasing the switch.

Advertising