78M6631 Firmware Description Document

Rev 2

27

3-Phase 4-Wire (Shunt)
An alternative to the previous configuration, the following figure shows a low-cost solution that is shunt-

based. As the previous configuration, the neutral is connected to V3P3 and is the reference potential for

both current and voltage measurements. The differential current inputs simplify the connections of the

shunt to the system

.

A

Neutral

B

C

VC

VB

VA

LOAD A

LOAD B

LOAD C

IAP

IAN

IBP

IBN

ICP

ICN

V

3P

3A

A

Neutral

B

C

78M6631

Shunt A

Shunt B

Shunt C

D

/Y

Non-Isolated Basic Delta Connection
The system is referenced to a phase (in this case phase B). The currents are sensed at the phases A and

C, and the third current is calculated. Although this implementation allows only two CTs, it does not allow

the measurement of current of each load individually.

A

B

C

VC

VB

VA

LOAD A-C

IAP

IAN

IBP

IBN

ICP

ICN

V

3P

3A

A

B

C

78M6631

LOAD A-B

LOAD B-C

D

/Y