2.11 Billing Tone Filter Commands

This command enables or disables the billing tone filter. If enable the user must specify the Receive Low
Pass Notch (RLPN) frequency of 12 or 16 kHz.

Syntax


FXOCTL:NN> billingtonefilter [enable|disable] [12khz|16khz]

Where:

NN

Shows the current active channel ID.

The following is a log of the billing tone filter commands:








Figure 18: Billing Tone Filter Command Logging Session

2.12 Threshold Override Commands

The FXO channel is operating with the parameter threshold configured by the channel initialization
procedure. This command can be used to override the threshold value with new threshold. Three
threshold parameters can be overridden:

1. Active Termination Loop (ACZ)

2. DC Current Voltage Characteristic Control (DCIV)

3. Ring Detect Threshold

Syntax


FXOCTL:NN> threshold acz xx dciv yy rgth zz

Where:

xx

0 – 15 (Active Termination Loop).

yy

0 – 3 (DC Current Voltage Characteristic Control).

zz

0 – 3 (Ring Detect Threshold).

NN

Shows the current active channel ID.

The following is a log of the billing tone filter commands:





Figure 19: Override Threshold Command Logging Session


FXOCTL:00> billingtonefilter enable 12khz

FXOCTL:00> billingtonefilter disable

Enable billing tone filter
with RLPN at 12 kHz.

Disable billing tone filter.

FXOCTL:00> threshold acz 5 dciv 2 rgth 2


Override threshold.