INSTALLATION INSTRUCTIONS (CONTINUED)

Water drainage:

- During dehumidifying modes, remove the drain

plug from the back of the unit and install the drain

connector (5/8” universal female mender) with 3/4”

hose (locally purchased). For models without drain

connector, just attach the drain hose to the hole.

Place the open end of the hose directly over the

drain area in your basement floor.

(See Fig. 23 & 24.)

- When the water level of the bottom tray reaches

a predetermined level,

the unit beeps 8 times and

the digital display area shows "P1." At this time

the air conditioning/dehumidification process will

immediately stop. However, the fan motor will

continue to operate (this is normal).

Carefully move

the unit to a drain location, remove the bottom drain

plug and let the water drain away. (See Fig. 25.)

Restart the machine until the "P1" symbol disappears.

If the P1 symbol will not clear after following the above

instructions and waiting a few minutes after restarting

the machine, call customer service.

Fig.23

Fig.24

Fig.25

NOTE: Be sure to reinstall the bottom drain plug

before using the unit.