background image

AIR

CONDITIONER NOT

COOLING ROOM, OR NOT

BLOWING COLD AIR

• Be sure unit is not too large or too small for the area of the room.
• Verify that all doors, windows, curtains and any other openings are closed off. Verify nothing is obstructing the

airflow to/from the unit and louvers such as curtains, etc.

• Allow enough time for room to cool, especially if outside temp is very high.
• Check that the filter is not dirty and louvers are open all the way and blowing in the direction desired.
• Check that unit is set to Cool Mode and that temperature is down enough (but not too low).
• If unit is near a heat source, such as a stove, etc., then relocate unit.
• If air coming from unit is cool to the touch, then unit is working properly; please double check the first three

bullet points above.

• If using Follow Me remote feature, move remote away from unit.
• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.

AIR CONDITIONER

CYCLING ON AND OFF TOO

FREQUENTLY OR NOT ENOUGH

• Be sure unit is not too large or too small for the area of the room.
• Make sure nothing is blocking the louvers.
• Make sure there is no dirt or debris inside the unit or on the filters.

AIR CONDITIONER COOLING BUT

ROOM IS TOO WARM - ICE

FORMING ON COOLING COIL
BEHIND DECORATIVE FRONT

• Outdoor temperature is below 64ºF (18ºC). To defrost the coil, set to Fan Only mode.
• Air filter may be dirty. Clean filter. Refer to Care and Maintenance section. To defrost, set to Fan Only mode.
• Thermostat is set too cold for night-time cooling. To defrost the coil, set to Fan Only mode. Then, set

temperature to a higher setting.

UNIT WILL NOT TURN ON

• Reset circuit breaker. Make sure there are not too many items (ie lamps, TV’s, etc.) working off the

same breaker.

• Check plug connection.
• If plug is operating on an on/off switch, be sure that the switch is ‘on’.
• Try plugging unit into another outlet.
• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.

UNIT BLOWS FUSES OR POPS

CIRCUIT BREAKER

• Make sure there are enough available amps on the circuit for the air conditioner.
• Large units which run on a 230v will require a dedicated 20 or 30 amp circuit.

REMOTE SENSING / FOLLOW ME

DEACTIVATING PREMATURELY

• Remote control not located within range. Place remote control within 20 ft and 180º radius of the front

of the unit.

• Remote control signal obstructed. Remove obstruction.

Issue

Possible Solutions

AIR CONDITIONER IS

MAKING NOISES

• Check to be sure the unit is free from debris. Verify nothing is obstructing the unit.
• Check the fan blade for cracks or chips.
• Make sure the window slider kit is properly and securely mounted inside the window.
• Clean the air filter.