28

PRG SERIES 400

®

POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL

Step

8. Connect console and other auxiliary devices to Front of House Breakout Box. Refer to

"Front of House

Breakout Module"

on page 18 for detailed connection diagram.

Figure 2-4: FOH Module Trunk Connection

WARNING:

A 400 Amp Disconnect

must be used

when house service is greater than 400 amps and more

than 10 feet from rack. 4/Ø feeders are rated for 400 amps or less. It is recommended that a PRG Series 400
400 Amp Disconnect be used. Refer to the Series 400 400 Amp Disconnect User Manual (02.9680.0200).

WARNING:

Ensure house service mains breaker and rack Master Switch are OFF before connecting mains

power cables to rack. Ground should

always

be connected first.

Step

9. At house service mains breaker (or 400 Amp Disconnect), turn power OFF.

Step 10. At Series 400 Rack, ensure Master Switch is OFF. To disengage Master Switch, pull down red protective

cover and press red button (Figure 2-5).

Step 11. Connect mains power cable Cam-Loks in the following order:

1) Ground, 2) Neutral 3) X Phase, 4) Y Phase, and 5) Z Phase.

Figure 2-5: Disengaging Master Switch and Connecting Cam-Loks

Step 12. Proceed to next section for Power Up instructions.

10

11

RESET

PORT 1

PORT 2

ETHERNET

Z-N

X-N

Y-N

DMX

TRUNK
DATA

LINK

Rx

Tx

Z-X

Y-Z

X-Y

FRONT of HOUSE MODULE

MODEL 20-9680-8615

6

AC LINE VOLTS

208V/15A

XØ-N

YØ-N

ZØ-N

XØ-YØ

YØ-ZØ

120V/15A

1

FOR BRANCH CIRCUIT USE ONLY

2

3

4

5

DMX INPUTS

ZØ-XØ

3

7

DMX Rx

RDM Rx

RDM Tx

RDM Tx

8

4

RESET

1

RDM Rx

DMX Rx

DMX Rx

RDM Tx

RDM Rx

2

DMX

9

5

Trunk Connector

TO FOH BREAKER MODULE

Master Switch ON Button

Master Switch OFF Button
(under red protective cover)

Cam-Lok Input CONNECTION

1) Ground
2) Neutral
3) X Phase
4) Y Phase
5) Z Phase

ORDER:

Connectors