Figure 2-12, Power and data distribution system user manual, Rack components may vary – PRG S400 User Manual 3.1 User Manual

Page 38

Advertising
background image

32

PRG SERIES 400

®

POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL

Notes:

+

When properly connected, a click inside the Breaker Module will be heard as the Trunk Cable key engages.

+

When properly connected, the green Trunk Data LINK indicator will be lit.

+

Connecting or disconnecting an A/B Switch while the system is powered up can cause an apparent switch
closure resulting in a change to the source system.

+

Connector numbers on the Breakout Boxes correspond to breaker switch numbers on the associated Breaker
Module. A Breakout Box connected to TRUNK A corresponds to the breaker switches for Trunk Circuit A, while a
Breakout Box connected to TRUNK B corresponds to the breaker switches for Trunk Circuit B. Refer to the
following diagram:

Figure 2-12: Breaker Switch and Connector Numbering Scheme

208V

6

DISTRIBUTION

POWER / DATA

TRUNK

DATA

ETHERNET

SYSTEM

S-400

Tx

LINK

Rx

XØ-YØ

YØ-ZØ

ZØ-XØ

CIRCUIT

TRUNK
CIRCUIT

15A x 6

B

208V

15A x 6

A

208V

TRUNK

1

2

3

INPUT 1

INPUT 2

PORT 1

PORT 2

A B

ZØ-XØ

XØ-YØ

YØ-ZØ

MODEL 20-9680-2915

15A x 12 CIRCUITS

4

5

RESET

RDM Rx

DMX Rx

RDM Tx

DMX

Trunk Data LEDs (A & B)
indicates valid Trunk cable
data link and data flow.

3

2

6

5

4

1

CIRCUIT USE

FOR BRANCH

ONLY

POWER / DATA

SYSTEM

DISTRIBUTION

S-400

15A x 6

208V

DMX Rx

RDM Tx

RDM Rx

DMX 1

DMX 2

ETHERNET

DATA

TRUNK

Tx

Rx

LINK

MODEL

20-9680-6615

XØ-YØ

XØ-YØ

YØ-ZØ

YØ-ZØ

ZØ-XØ

ZØ-XØ

Breaker Switch 1 corresponds
to Connection 1 on Breakout Box,
Switch 2 corresponds to
Connection 2, etc.

BREAKOUT BOX

BREAKER MODULE

Trunk connection to
TRUNK A at rear of
Breaker Module

15A 208V MODELS SHOWN

Rack Components May Vary