Audio panel mounting rack installation, Cable harness wiring, Noise – PS Engineering PDA360EX Installation Manual User Manual

Page 9: Udio, Anel, Ounting, Nstallation, Able, Arness, Iring

Advertising
background image

PS Engineering Inc. ®

PAR100EX Audio Selector Panel and Intercom System

Installation and Operator’s Manual

200-760-0000

Page 2-2

Rev. 12, Jan. 2014

Figure 2-1 M760REM VHF Transceiver (Remote Mount)

2.3.4

Audio Panel Mounting Rack Installation

Remove the unit from the mounting tray by unscrewing the 3/32" hex-head screw that is in the center of
the unit. Use caution to avoid hitting the photo-detector lens. Carefully slide the unit free of the tray. Set
the unit aside in a safe location until needed. Install the tray using six clip nuts (475-630-0002), and six
FHP 6-32 x ½" screws (475-632-0012). The audio selector panel must be supported at front and rear of
the mounting tray.

2.4 Cable Harness Wiring

Referring to the appropriate Appendix, assemble a wiring harness as required for the installation. All
wires must be MIL-SPEC in accordance with current regulations. Two- and three-conductor shielded wire
must be used where indicated, and be MIL-C-27500 or equivalent specification. Proper stripping, shield-
ing and soldering technique must be used at all times. It is imperative that correct wire be used.

Refer to FAA Advisory Circular 43.13-2B for more information. Failure to use correct techniques may
result in improper operation, electrical noise or unit failure. Damage caused by improper installation will
void the PS Engineering warranty.

2.4.1

Noise

Due to the variety and the high power of radio equipment often found in today's general aviation aircraft,
there is a potential for both radiated and conducted noise interference.

The PAR100EX power supply is specifically designed to reduce conducted electrical noise on the aircraft
power bus by at least 50dB. Although this is a large amount of attenuation, it may not eliminate all noise,
particularly if the amplitude of noise is very high. There must be at least 13.8 VDC present at the connec-
tor, J2 pins 8 & 9, of the PAR100EX for the power supply to work in its designed regulation. Otherwise, it
cannot adequately attenuate power line noise. Shielding can reduce or prevent radiated noise (i.e., beacon,
electric gyros, switching power supplies, etc.) However, installation combinations can occur where inter-
ference is possible. The PAR100EX was designed in a RFI hardened chassis and has internal Electro-
magnetic Interference (EMI) filters on all inputs and outputs.

Ground loop noise occurs when there are two or more ground paths for the same signal (i.e., airframe and
ground return wire). Large cyclic loads such as strobes, inverters, etc., can inject noise signals onto the
airframe that are detected by the audio system. Follow the wiring diagram very carefully to help ensure a
minimum of ground loop potential. Use only Mil Spec shielded wires (MIL-C-275000, or better). Under