Form CP-PREEVA-GC, P/N 212063 R7, Page 3

FIGURE 1 - Burner and

Low Voltage Electrical

Section

(Depending on size,

controls may appear

differently, but conversion

instructions are the

same.)

Pressure Switch

If installation is above 6000 ft (1830M),

pressure switch may need to

be changed. Follow high altitude

instructions on page 4.

Control Side

Electrical Compartments

Burner with Venturi Tube (See FIGURE 2A)

Gas Valve

Follow manufacturer's

instructions to install

regulator spring kit.

4. Select and Install Burner Orifice

WARNING

Do not attempt to drill orifice. Use factory-supplied orifice only.

4A. Select orifice.

Because each kit is designed to convert more than one size of heater, there are

two or three burner orifices per kit. From

TABLE 1 below, find the marking that

appears on the orifice for the heater being converted. Select the orifice from the

kit that has the marking required for the size of heater. The other orifice(s) will

not be used in this conversion.

TABLE 1 - Burner

Orifice P/N’s and

Markings

Burner Orifice - PREEVA

®

Models PDH, SDH, and RDH

Size

75

100

125

150

175

200

225

250

300

350

400A

Natural

Gas

P/N 196855 205430 211851 131581 196891 196892 221121 208255 221122 221123 196897

Marking

#19

#11

#3

5.9MM

E

6.8MM 6.95MM

L

8.0MM 8.7MM 9.6MM

Propane

P/N 196852 205720 196838 196898 196899 196900 196901 196902 196903 196904 196905

Marking

#39

2.9MM

#30

9/64"

#24

4.1MM 11/64"

#14

#8

#3

5.8MM

4B. Locate the Orifice on all Sizes AND the Air Restrictor Plate on Sizes 75, 100,

125, 150, and 175

Refer to FIGURES 2A and 2B.

FIGURE 2A -

1) Location of the

Burner Orifice on all

Models & Sizes

2) Location of the Air

Restrictor Plate on

SIZES 75, 100, 125, 150,

and 175 when installed

for use with Propane

Burner Orifice (NOTE: Before

installing the new orifice, verify

the marking with the size listed in

TABLE 1, page 3.)

Gas Flow from

Gas Valve

Venturi

Tube

Air Restrictor Plate ONLY FOR PROPANE -

Applies to Sizes 75, 100, 125, 150, and 175

when using propane only.

(Tabs are

not bent;

see below.)