Wiring dia gram – Reznor P6SD (3ph) Unit Installation Manual User Manual

Page 18

Advertising
background image

18

Figure 11. Wiring Diagram-Fixed Torque Motor

7107640

Low

Voltage

Terminals

T2

DFT

TEST

T1
T2

C
Y
O

W2

R

DFT

E

C
Y
O

W2

R
E

DF1 DF2

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

9

8

1

7

6

5

4

3

2

9

8

1

7

6

5

4

3

2

L1

L2

L3

T1

T2

T3

T2

T1

T3

R

C

S

T2

T1

N

G

L

C

T3

T4

T5

NC

NO

C

T

O 208/230

V

A

C

POWER SUPPL

Y

9

8

1

7

6

5

4

3

2

9

8

1

7

6

5

4

3

2

3 PHASE

C

OMPRESSOR

CAP

A

CIT

O

R

HEA

TER

PL

UG

OUTDOOR

FAN MO

T

OR

DEFROST

SENSOR

RE

VERSING

V

AL

VE SOLENOID

EC

ONOMIZER

PL

UG

B

T

O INDOOR

THERMOST

A

T

HIGH PRESSURE

SWIT

CH

G

EC

ONOMIZER

PL

UG

T

O DISCHARGE

AIR SENSOR

3 AMP

FUSE

BL

OWER

RELA

Y

BL

OWER

MO

T

OR

TRANSFORMER

24V

240V

208V

CO

M

CCH

BLACK

BLACK

BLACK

RED

RED

RED

RED

RED

RED

RED

BL

UE

YELL

OW

BL

UE

BL

UE

WHITE

WHITE

WHITE

BLA

CK

BLA

CK

BLA

CK

BROWN

BROWN

ORANGE

YELL

OW

YELL

OW

YELL

OW

YELL

OW

GREEN

GREY

GREY

GREEN

GREEN

GREEN

GREEN

ORANGE

WHITE

WHITE

RED

ORANGE

BROWN

ORANGE

YELLOW

BL

UE

BLA

CK

BLACK

BLA

CK

BLA

CK

BLA

CK

BL

UE

RED

BK

RED

WHITE

WHITE

BLA

CK

BLA

CK

208/230 V

olt

z

H

0

6

e

s

a

h

P

e

er

h

T

p

m

u

P

t

a

e

H

d

e

g

a

k

c

a

P

el

bi

tr

e

v

n

o

C

NO

TES:

1.

Disconnect all po

wer bef

ore ser

vicing.

2.

For suppl

y connections use copper conductor

s onl

y

.

3.

Not suitab

le on systems that e

xceed 150V to gr

ound.

4.

If an

y of the original wire as supplied with the furnace

m

ust be replaced,

it m

ust be replaced with wiring

material ha

ving a temperature rating of at least 105°C.

5.

For suppl

y wire ampcities o

ver

current pr

otection,

see

unit rating plate

.

1.

Couper le courant a

v

ant de faire letretien.

2.

Emplo

y

ez uniquement des conducteur

s en cuivre

.

3.

Ne con

vient pas aux installations de plus de 150

V

a la terre

.

FIELD WIRING

LEGEND:

LO

W V

OL

T

A

GE

HIGH V

OL

T

A

GE

DEFROST BO

ARD OPERA

TION:

1 CL

OSES DURING DEFROST

. RA

TNG:

1 A MAXIMUM

2 OPENS DURING DEFROST RA

TING:

2 HP A

T 230

V

A

C MAXIMUM

3 CL

OSED

WHEN

“Y

” IS ENERGIZED

. OPEN

WHEN

“Y

” IS DEENERGIZED

.

PROVIDES

“OFF”

DELA

Y

TIME OF 5 MIN

WHEN

“Y

” IS DEENERGIZED

.

4

WIITH DFT CL

OSED AND

“Y

” ENERGIZED

, C

OMPRESSOR RUN

TIME IS A

C

CUMLA

TED

.

OPENING OF DFT DURING DEFROST OR INTER

V

AL PERIOD RESET

S

THE INTER

V

AL

T

O 0.

NO

TE:

S

ee Installation

Instruc

tions f

or wiring

,

application,

and

Inf

ormation c

onc

erning

acc

essor

y Heat K

its and

other options

.

WIRING