SAfeTy INSTRucTIONS

WARNING: When using this device, always exercise
basic safety precautions, including the following:
• Read all instructions before installation or use.
• Never connect this device to any electrical circuit

with other than 12 or 24 volt direct Current or
exceed the amperage draw listed below.

• Never install the indicator panel in an atmosphere

with potentially flammable or explosive vapors.

• Never install the probe cap with float switches

into a tank that contains anything other than
fresh, gray or black water.

CAUTION: dropping or rough handling of float
switches may result in damage.

feATuReS

DTM04

DTM08

DTM12

Tank Monitor Application chart

DTM04

DTM08

DTM12

Blackwater waste

Freshwater supply

Graywater waste

Probe

cap

Adjustable

Stems

float Switches

Tank Monitor Systems

Dometic Tank Monitor Systems permit remote sensing of liquid
levels in black or gray waste water, or potable freshwater tanks.
Three float switches, which activate a set of four lights, are installed
in the desired tank. One float activates a “Full” light when the liquid
is within 2 inches (51 mm) of the top inside surface of the tank. The
other float switches are mounted on adjustable stems and can be
positioned to within 2 inches of the tank bottom. The stems are
semi-flexible and flex with the sloshing of the tank contents. One
float can be positioned to sense when the tank is empty and the
others to sense when the tank is 1/4 or 1/2 full, depending on the
application.