SeaLand 8911RV User Manual

Page 4

Advertising
background image

® Registered; ™ Trademark of Dometic Corporation

© Dometic Corporation

600346694 01 12/11

SeaLand MasterFlush Toilets

RV Installation Appendix

CONVERSION TABLE

Wire – AWG to mm

2

Feet to Meters

AWG

14

12

10

Ft

10

15

20

30

50

mm

2

2.5

4.0

6.0

M

3.1

4.6

6.1

9.2

15.2

Wire size per length of run*

0-15 ft.

16-30 ft.

31-50 ft.

12 volts DC

#14

#12

#10

* Distance from circuit breaker to electronic control module.

WIRE SIZING CHART

When installing a SeaLand macerator toilet in a recreation vehicle, please use the following wiring
information. Refer to MasterFlush toilet parts list for complete macerator toilet wiring diagram.

Installation notes

• Each toilet must have its own circuit breaker or fuse.
• Wire sizes must be appropriate for the installation. All other installation factors must be in

accordance with ISO electrical standards.

• Always use stranded copper wire (preferably tinned).
• Always use crimp-type wire connections. Do not use wire nuts (they corrode).

Warning!
Hazard of Shock or Fire: Always use recommended fuse, circuit breaker and wire size.
Failure to do so can cause the loss of property and life.

Wiring / Electrical Connections

Advertising
This manual is related to the following products: