Product Name:

tankmanager

Automatic Discharge Pump Controller and Level Indicator

Electrical:

Output Current Capability
maximum Relay Rating for 2 or 24 VDC Discharge Pump: 40 amps inrush, 30 amps

continuous.

Float Switch Rating: 20 watts with resistive load.

Current Consumption
“Standby” Current Draw:

2 Volts DC: 0.06 amps

24 Volts DC: 0.06 amps

“Pump On” Current Draw (not including pump):

2 Volts DC: 0.90 amps

24 Volts DC: 0.095 amps

Materials:

Control Panel face Plate – polystyrene with protective coating

Keylock Switch – stainless steel facing

Key – nickel-plated brass

Control Module Enclosure – ABS

CONTROL MODULE

. Select a mounting location as close as possible to the peripheral equipment, such as the level indicator cap,

discharge pump, and vacuum generator. this will allow all connectors to be attached without running any ad-

ditional wiring harnesses.

2. make sure the control module will not be in direct contact with water and oil.

3. Attach the control module to the selected mounting area with four screws (not supplied).

4. Route wiring according to the wiring diagram enclosed. If the mating connectors are not available, simply cut

off the existing connectors and use any approved connector.

CONTROL PANEL

. Select a mounting location away from direct contact with water and oil.

2. Confirm clearances for the panel behind the mounting surface. You will need a minimum clearance of

3 inches.

3. Cut out the mounting holes for the control panel. (See template included in this manual for cut-out and hole

locations.)

4. Do not mount the control panel until all wiring is routed to the panel.

5. Route wiring following the wiring diagram enclosed. If the mating connectors are not available, simply cut off

the existing connectors and use any approved connector.

6. mount the control panel with the four #4 x 3/8-inch long pan-head stainless steel screws provided.
Notes:

the lens colors for the control panel lights are as follows:

the keylock switch wiring colors are as follows. Wires connect to the terminals on the back of the switch:

Check Seacock

(Optional)

Discharge Pump

On

Empty

Low

Mid

full

Green

Yellow

Amber

Red

Green

Yellow

Terminal 1

Terminal 2

Terminal 7

Terminal 8

Configuration 1

(Auto Start)

Configuration 2

(Manual Start)

Red

Red

Brown

Brown

Blue

N/A

Red

Blue

SPECIfICATIONS

INSTALLATION INSTRUCTIONS

Advertising