SeaLand TankWatch 1 Level Monitoring System User Manual

Page 2

Advertising
background image

6

5

7

A.

For a 12V system:

Connect the

red wire

through a 1/2-amp fuse

(not supplied), to a

positive 12VDC source.

For a 24V system:

Connect the

blue wire

through a 1/2-amp fuse

(not supplied), to a

positive 24VDC source.

B. Connect the white wire

from the red LED to one

of the white wires on the

Float Switch Assembly.

C. Connect the remaining

white wire from the Float

Switch Assembly to the

negative DC source.

Place the Switch Assembly into the tank with the

gasket in place. Drive four No. 8 x 3/4” mounting

screws, using care to tighten evenly. DO NOT

OVER-TIGHTEN.

Mount the Indicator Assembly. Fasten with the

two No.4 x 1/2” screws provided.

600340507 3/07

Following the wiring diagram, route wires on a 12VDC

or 24VDC circuit using good electrical practice.

SPECIFICATIONS

MODEL INFORMATION

Part Number

Description

313000312

TankWatch 1 Panel, Float Assembly

Average Current Consumption: 0.016 amps