Dometic 8700 Series MasterFlush Toilet

Installation

5 Installation

5.1

Fresh water system layout - marine application

5.2

Raw water system layout - marine application (additional components required)

Note

Use cold water only. Include shut-off valve in water line for maintenance purposes.

Notes

Use cold water only. Include shut-off valve in water line for maintenance purposes.
Use primary and secondary raw water filters.
Raw water pump MUST NOT be demand-type. Pump is controlled by control module.
Install vented loop as shown. It must be equipped with integral check valve that permits air into line to
prevent siphoning .

Dometic macerator toilets can operate with an
onboard pressurized freshwater system with a
minimum flow rate of 2.5 gpm (9.5 lpm) at the
toilet. Onboard fresh-water demand systems
include a water pump that automatically draws
water from a water storage tank when a valve

Dometic macerator toilets can flush on seawater but require a separate pump for this purpose. The
pump is activated by the signal from the toilet’s electronic control module that would operate the
integral water valve in a fresh water system . If the raw water pump draws more than 18 amps of
current, a 12 or 24 V DC electrical relay must be installed.

anywhere in the piping system is opened .
Dometic toilets are equipped with an electrically
operated water valve and a backflow preventer
to prevent contamination of onboard potable
supplies .

6

7

VENT

FITTING

SEACOCK

VENT

FILTER

DISCHARGE

PUMP

DECK

DISCHARGE

“FULL” LEVEL

PROBE (opt.)

CONTROL

MODULE

CONTROL

MODULE

MACERATOR

TOILET

MACERATOR

TOILET

FLUSH

SWITCH

PANEL

FLUSH

SWITCH

PANEL

0.5 in./13 mm

FRESH WATER

HOSE

0.5 in./13 mm

WATER HOSE

0.625 in./16 mm HOSE

1 in./25 mm HOSE

SEACOCK

TO SUCTION SIDE OF

RAW WATER PUMP

FINE WATER FILTER

(100 MESH)

SMALL ENGINE INTAKE STRAINER (COARSE)

RAW WATER

PUMP

WATER LINE

HOLDING TANK

(cut-away view)

VENTED LOOP/CHECK VALVE

Must be 8 in./203 mm above water

line during all conditions of heel,

trim or load