SeaLand VacuFlush SW24 Vacuum Pump User Manual

Important notice

Advertising
background image

Dimensional
Specifications

Before installing the pump, consider the following:
1. Vacuum pump must be mounted horizontally only.
2. The pump can be mounted from 2 to 15 feet from the vacuum

tank. The maximum distance is 15 feet.

3. Mount vacuum pump at same level or lower than vacuum tank

outlet. Do not mount vacuum pump higher than the vacuum tank
outlet.

4. The maximum head pressure on the discharge of the pump must

not exceed 6 feet.

Note: Two-toilet systems require a vacuum pump and vacuum tank for each toilet.
It provides the benefit of a totally redundant operating toilet in case of failure in one
toilet. Two pumps greatly reduce hose runs and system complexity.

Installing the pump:
1. Make sure the vacuum pump is properly located before

proceeding. Place the vacuum pump on the surface to be mounted. Position as needed. Using a center
punch, mark the four slotted holes in the pump feet. Remove pump.

2. Using a 3/16-inch drill bit, drill the four mounting holes. Use a #14 wood screw to secure pump.
3. The flow direction is indicated on the pump body.
Stainless steel wall mounting bracket is available as optional accessory – P/N 341505.
Wiring the pump:
Wire the S-series pump as shown in the wiring diagram. Use multistranded copper wire. Proper fuse or circuit
breaker size is extremely important for pump and wire protection (see chart above). Overfusing this pump will result
in warranty invalidation.

Electrical schematic also shows installation of optional “night
switch”.

Electrical
Specifications

S Vacuum Pump

with W Motor

Installation Instructions

Dometic Corporation, Sanitation Division

13128 State Rt. 226, P.O. Box 38

Big Prairie, OH 44611-0038 USA

330-496-3211

1-800-321-9886 • Fax: 330-496-3097

® Registered; ™ Trademark of Dometic Corporation

© Dometic Corporation

IMPORTANT NOTICE

VacuFlush

®

sanitation systems must be installed according to

Dometic’s recommended procedures. Do not attempt installation without first contacting a SeaLand

Product certified dealer or Dometic Corporation.

Model

Volts (DC)

Avg. Amp Draw GPH Fuse/Breaker

Wire Size

Weight

SW12

12

6

230

10 amps

12-14 ga.

8 lbs.

SW24

24

3

230

5 amps

14-16 ga.

8 lbs.