Installation, Electrical power requirements, Air supply – Sonics X-Press Integrated Welder User Manual

Page 10: Setting up, Electrical power requirements air supply

Advertising
background image

I N S T A L L A T I O N

ELECTRICAL POWER REQUIREMENTS

The press requires a fused, single-phase, standard 3-terminal grounding

type receptacle capable of supplying the requisite voltage and current. Refer

to the table below for power specification.

AIR SUPPLY

The press requires a source of dry, filtered (5 micron), oil-free, compressed

air capable of supplying a constant line pressure of 85 psig. (586 kPa / 6 bar)

at a minimum capacity of 2 CFM.

SETTING UP

The press should be installed in a clear, uncluttered location that is free from

excessive dirt, dust, corrosive fumes, and temperature and humidity ex-

tremes. The selected installation site should be near the electrical power and

air supply sources and away from any equipment that generates abnormally

high electrical transients. Observe the following additional instructions when

installing the press:

a. The press should be placed on a sturdy, level table or bench capable of

supporting a minimum of 500 pounds (227 kg).

b. Do not place anything on top of the press. The ventilation grille should not

be covered by any items. Periodically check the grille and clean as

necessary.

Model

Power Rating

115 vac

230 vac

XP1200

1200w

20 amps

10 amps

XP2200

2200w

N/A

20 amps

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L X - P R E S S

9

Do not connect the press

to an air source supplied

by a compressor lubricated

with synthetic oils or oils

containing phosphate

esters or chlorinated hydro-

carbons. This type of

lubricant may cause the air

filter to malfunction, and

the plastic bowl to rupture.

The line cord is equipped

with a 3-prong, grounding

plug. Do not, under any

circumstances, remove the

ground prong. The plug

must be plugged into a

mating 3-prong, grounding

type outlet.

POWER SPECIFICATIONS