Sonics X-Press Integrated Welder User Manual

Page 15

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L X - P R E S S

14

5. ENERGY key (active on XPE models only) which allows selection and

display of the following energy settings and permits adjustment of the

energy parameters a. through c. below in 1 joule increments (from 0 to

999,999 joules):

a. Energy Setting

b. Energy Limit Low

c. Energy Limit High

For a complete explanation of these parameters, refer to page 19.

6. AMPLITUDE key which controls adjustment of the amplitude setting,

relating to the system’s high-frequency vibrations over the full operating

range. Refer to page 19 for more information. (Major adjustments of

amplitude can be made through the use of different boosters – see page

27.)

7. FN KEY. Option not available on this model.

8. TEST key which can be used to test ultrasonic operation and displays

idle losses of converter/booster/horn as a percentage of maximum power

when key is depressed. Also functions as a frequency display. Refer to

page 16 for more detailed information.

9 O.L. RESET key which resets the power supply following an overload

condition. Red LED in upper left corner indicates an overload condition

exists. Refer to page 20 for complete information.

10. 0-9 NUMERIC KEY PAD which allows input of numeric data or

numeric selection options by pressing the keys.

11. CLEAR key which cancels a prior parameter value when a new value is

to be entered.

12. ENTER/REVIEW key which Enters data into the system as keyed in with

the numerical keys and displayed on the LCD screen. In Review function,

displays the alarm, mode and cycle information.