ACTUATION

The press is equipped with two maintained anti-repeat (non-tie-down) palm

buttons, one located on the left and one on the right side of the base of the

press. Both palm buttons must be pressed simultaneously to activate the

press to cycle the welder. To operate the press, follow these simple steps:

1. Depress both black palm buttons simultaneously.

2. Once the horn comes in contact with the part, the pressure switch closes

and the ultrasonics are activated, release the palm buttons. If you release

the buttons before contact is made, the head will immediately return to its

“home” position.

EMERGENCY STOP

To abort the press during welding, simply press the red EMERGENCY STOP

button located at the front center of the press base.

Once the EMERGENCY STOP button has been depressed, the head will

retract and return to its “home” position. Simply rotate the EMERGENCY

STOP button clockwise 1/4 turn to release the press for further operation.

NOTE: Power cannot be

shut off once the weld

cycle has started.

Termination of cycle can

only be achieved by using

the EMERGENCY STOP

button.

The equipment has safety

devices that require both

hands to be on the palm

buttons until the horn

contacts the workpiece. Do

not defeat or modify

these safety devices.

Do not use with a

footswitch unless alternate

means of pinch-point

protection is provided.