Gs (e pl ph fn a fn = 4 – CITIZEN CT-S300 User Manual

Page 100

Advertising
background image

— 95 —

fn = 4: Function 4 Sending the Set Memory Switch Value

GS (E pL pH fn a fn = 4

[Code]

<1d>H<28>H<45>pL pH fn a

[Range]

(pL + pH

× 256) = 2

fn = 4

a = 1, 2, 3, 4

[Outline]

• Sends the content of memory switch set in “a”.

• Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6, ....

OFF: 30H (“0”)

ON : 31H (“1”)

Hex.

No. of Data

Header

37H

1

ID

21H

1

Data

30H or 31H

8

NULL

00H

1

Advertising