Gs (e pl ph fn a d1...cdk fn = 11 – CITIZEN CT-S300 User Manual

Page 111

Advertising
background image

— 106 —

fn = 11: Function 11 Setting Communication Conditions of Serial

Interface

GS (E pL pH fn a d1...cdk fn = 11

[Code]

<1d>H<28>H<45>pL pH fn a d1..dk

[Range]

3 (pL + pH

× 256) 65535 (0 pL 255, 0 pH 255)

fn = 11

1 a 4 (Not changed in other than specified range)

48 d 57 (Not changed in other than specified range)

1 k 6

[Outline]

Sets the communication conditions of serial interface specified by “a”.

• a = 1: Setting baud rate

Baud Rate

d1

d2

d3

d4

d5

d6

2400

50 (“2”)

52 (“4”)

48 (“0”)

48 (“0”)

—

—

4800

52 (“4”)

56 (“8”)

48 (“0”)

48 (“0”)

—

—

9600

57 (“9”)

54 (“6”)

48 (“0”)

48 (“0”)

—

—

19200

49 (“1”)

57 (“9”)

50 (“2”)

48 (“0”)

48 (“0”)

—

(Default)

38400

51 (“3”)

56 (“8”)

52 (“4”)

48 (“0”)

48 (“0”)

—

• Operates only in printer function setting mode.

• Which of dip SW or memory SW is used at initialization depends on “Selecting

communication condition setting” of dip SW1-1.

• a = 2: Setting to specified parity

d1

Parity Setting

48 (Default)

No parity

49

Odd parity

50

Even parity

d1

Flow Control

48 (Default)

DSR/DTR

49

XON/XOFF

• a = 3: Setting to specified flow control

d1

Setting Data Length

55

7-bit length

56 (Default)

8-bit length

• a = 4: Setting to specified data length