Gs (e pl ph fn a fn = 6 – CITIZEN CT-S300 User Manual

Page 103

Advertising
background image

— 98 —

fn = 6: Function 6 Sending the Set Customized Value

GS (E pL pH fn a fn = 6

[Code]

<1d>H<28>H<45>pL pH fn a

[Range]

(pL + pH

× 256) = 2 : (pL = 2, pH = 0)

fn = 6

1 a 3, a = 5, 6, 97, 116, 201, 202

[Outline]

• Sends the set value of customized value set by “a”.

Hex.

No. of Data

Header

37H

1

ID

27H

1

Customized value No.

30H ~ 39H

1 ~ 3

Separation number

1FH

1

Customized value

30H ~ 39H

1 ~ 5

NULL

00H

1

a

Sending Data

1st Byte

2nd Byte

3rd Byte

3

51 (“3”)

5

53 (“5”)

6

54 (“6”)

97

57 (“9”)

55 (“7”)

116

49 (“1”)

49 (“1”)

54 (“6”)

201

50 (“2”)

48 (“0”)

49 (“1”)

202

50 (“2”)

48 (“0”)

50 (“2”)

• Configuration of customized value No.

• a = 3: When paper width is specified

* No function with CT-S300

Setting Status

Sending Data

Stored

Power

1st Byte

2nd Byte

3rd Byte

4th Byte

5th Byte

Value

Width

1

58 mm

49 (“1”)

2*

60 mm

50 (“2”)

3

80 mm

51 (“3”)

Advertising