Calibration, Gram/pulse new calibration, Warnings – TeeJet LH INTELLITRAM 500 User Manual

Page 14: Clutch left/right

Advertising
background image

E

NCODE

LH

”I

NTELLITRAM

” 500 O

PERATORS MANUAL

14

LH A

GRO

CALIBRATION

GRAM/PULSE

The weight, in gram, per pulse can be encoded directly if known.

NEW CALIBRATION

The procedure for calibration is thus:

1. Move the cursor to “New calibration” and press the ENTER key.
2. Turn the drill shaft a suitable number of rotations (see the seed drill

instruction book), the computer counts the number of pulses. Press the
ENTER key when finished.

3. Weigh the amount released (exactly) and enter this weight. Press the

ENTER key.

4. The calculated weight per pulse is now shown on the display.

WARNINGS

Key

Description

Warning on.

Warning off.

CLUTCH LEFT/RIGHT

The clutch warning is given if tramlines are made when they should not be and
visa versa.
Encode whether the warning is active (on) or not active (off). Use the program
keys 1 & 2 to switch the warning on or off.
These warning encodements are not shown if pneumatic seed drill has been
selected under machine type in the system menu (see page 22).

Advertising