Tie Down Vector Dynamics Foundation System for Wind Zones IBC 2009 User Manual

Page 10

Advertising
background image

Page

10 4/3/2013

Example of a Single Section 14' x 72' H om e

WIND ZONE I for Single Section Homes

Using V ector Dynamics Foundation System s

Soil Classifications:

2, 3, 4A & 4B

Soil Bearing Capacity:

1,000 PSF Minimum

Anchors Required:

30" with 2-4" helix anchors (#59095) & 12" Stabilizer Plates (#59292)

with 1-1/4" Frame T ie s

Home Length

Vector Systems

Anchors Required

24+" Piers

Longitudinal

Required

Per Side Up To 24" Pier

Systems* (LSD)

0 to 72'

3

2

3

1 (2 Struts)
1 (2 Struts)

73' to 90'

4

3

4

NOTES:

V ector Systems should be spaced as

symmetrical as possible along the length of

the home. Pier spacing must be consistent

with home manufacturers instruction and/or

state requirements.


* One Longitudinal Vector System is made up of 2 struts,
which can be used separately
.

V ector System s

Longitudinal

(LSD)

Longitudinal

(LSD)

Anchors & Stabilizers

Wind Zone I

Advertising