Tie Down Vector Dynamics Foundation System for Wind Zones IBC 2009 User Manual

Page 11

Advertising
background image

Page

11 4/3/2013

Example of a Double Section 28' x 72' Home

WIND ZONE I for Double Section Homes

Using Vector Dynamics Foundation Systems

Soil Classifications:

2, 3, 4A & 4B

Soil Bearing Capacity: 1,000 PSF Minimum

Anchors Required*:

None (*Marriage wall and sheer wall anchors may be required by home manufacturer.)

Home Length

Vector Systems

Anchors Required

Longitudinal

Required

Per Side

System

1

(LSD)

0 to 48'

2

0*

1 (2 Struts)
1 (2 Struts)
1 (2 Struts)
1 (2 Struts)

49' to 71'

3

0*

72' to 84'

4

0*

85' to 90'

5

0*

NOTES:

*No anchors required for pier heights up to

46” for 28’-36’ wide, 38” for 24’ wide.

Vector Systems should be spaced as

symmetrical as possible along the length of

the home. Pier spacing must be consistent

with home manufacturers instruction and/or

state requirements.

Vector System

Longitudinal (LSD)

Longitudinal (LSD)

Vector Systems

Vector System

1

One Longitudinal Vector System is made up of 2 struts,

which can be used separately.

Wind Zone I