11

10003929

LO

HI

Turn

counterclockwise

to decrease

flame height.

Turn clockwise

to increase

flame height.

Fig. 18

FLAME ADJUSTMENT

Flame adjustment is accomplished by rotating the Hi/Lo
adjustment knob located near the centre of the gas
control. (Fig. 18)

It is important to periodically perform a
visual check of the pilot and the burner
flames. Compare them to the pictorials
illustrated below (Fig.19 and 20). If any
of the flames appear abnormal call a
service person.

FLAME CHARACTERISTICS

L O

HI

Turn

counterclockwise

to increase

flame height.

Turn clockwise

to lower

flame height.

Fig. 20

3/8" - 1/2"

Fig. 19

SIT Pilot

PSE Pilot

IRHEDV32

SIT Valve

Honeywell

Valve

Advertising