Water Heater Maintenance

Do not use automotive, ethylene glycol or
petroleum-based antifreeze. Do not use
any undiluted antifreeze. This can cause
severe personal injury, death or substantial
property damage.

Water from opened drain valves, unions
and other connections may be extremely
hot. To avoid severe personal injury, death
or substantial property damage:

- Tighten all drain hose connections.

- Direct hot water away from all persons.

Draining Inner (Domestic Water) Tank

(See Domestic Piping Fig. 1 page 8)

1. Disconnect power supply to water heater.

-

If outer (boiler water) tank pressure

is greater than 15 psig, relieve boiler
pressure and close isolation valves
before proceeding.

2. Close system supply isolation valve.

3. Connect a hose to domestic water drain valve

at cold water inlet. Hose should extend to
drain at floor level to allow siphoning of
domestic water tank.

4. Open hot water faucet at highest point above

heater.

5. Open domestic water drain valve to start

siphoning.

6. When draining is complete, close hot water

faucet and domestic water drain valve.

Draining Outer (Boiler Water) Tank

1. Disconnect power supply to water heater.

2. Close boiler water isolation valves between

boiler and water heater.

3. Connect hose to boiler water drain valve at

water heater. Open and drain water to a safe
place.

4. To speed draining procedure, loosen air vent

on top of tank.

5. When draining is complete, close drain valve

and retighten air vent.