Phase iii, Installation, Chart 1 – TriangleTube TR Series User Manual

Page 9

Advertising
background image

Phase III

®

6

Installation

Water Hammer

Dishwashers, clothes washers and fast-closing pos-
itive shut-off valves incorporated in the system all
contribute to creating water shock. Install a water
hammer arrester to prevent damage to pipes and
appliances. See device manufacturer’s instructions
for application and installation.

Water hammering within the domestic pip-
ing system can cause premature failure of
the inner tank of the water heater. This type
of failure is NOT
covered under warranty.

Vacuum Breaker

Installing a vacuum breaker on the domestic cold
water outlet will prevent damage to the inner tank
if a negative pressure is developed in the domestic
supply line. See manufacturer’s instructions for
application and installation of the vacuum breaker.

General Piping

•

For domestic water piping diagrams, see page 8
thru 10.

•

See pages 11 through 14 for:

- Boiler water piping

- Multiple water heater domestic and boiler

piping.

•

See Chart 1 for domestic and boiler piping
connections.

•

All plumbing must meet or exceed all local,
state and national plumbing codes.

•

Use pipe dope or tape suitable for potable
water systems.

•

Use isolation valves to isolate system components.

Domestic Piping

•

Union on domestic hot water outlet should be
piped at a higher elevation than domestic water
drain valve. This will make draining the water
heater easier.

•

Install unions for easy removal of water heater.
Use dielectric unions or couplings to protect

NOTICE

Chart 1

Connections - NPT

Recirculation Dip Tube

Draining Dip Tube

Recommended

Water Heater

Domestic

Boiler Water

Auxiliary

Length

Diameter

Length

Diameter

Minimum

Model

Water

Supply/

Connection

inches

inches

inches

inches

Boiler Piping

Inlet/Outlet

Return

Diameter (inches)

TR-20

3/4

1

3/4

34

3/4

34

3/4

1

TR-30

3/4

1

3/4

43

3/4

43

3/4

1

TR-36

3/4

1

3/4

52

3/4

52

3/4

1

TR-45

1

1 1/4

3/4

25

3/4

47

3/4

1 1/4

TR-60

1

1 1/4

1

25

1

54

1

1 1/4

TR-80

1 1/2

2

1 1/2

25

1 1/2

48

1 1/2

2

TR-100

1 1/2

2

1 1/2

32

1 1/2

61

1 1/2

2

TR-120

1 1/2

2

1 1/2

32

1 1/2

61

1 1/2

2

SMART 20

3/4

1

3/4

23.5

3/4

23.5

3/4

1

SMART 30

3/4

1

3/4

34

3/4

34

3/4

1

SMART 40

3/4

1

3/4

43

3/4

43

3/4

1

SMART 50

3/4

1 1/4

3/4

25

3/4

52

3/4

1 1/4

SMART 60

3/4

1 1/4

3/4

34

3/4

62

3/4

1 1/4

SMART 80

1 1/2

1 1/2

1 1/2

25

1 1/2

48

1 1/2

1 1/2

SMART 100

1 1/2

1 1/2

1 1/2

32

1 1/2

61

1 1/2

1 1/2