Xdv direct vent gas fireplace large lava rock, Burner lava rock placement, Flame & temperature adjustment – Vermont Casting 36XDV User Manual

Page 31: Manual on/off valve, Flame characteristics, Inspecting the venting system

Advertising
background image

10009383

31

XDV Direct Vent Gas Fireplace

Large Lava Rock

The large bag of lava rock provided with this fireplace
must be placed on the firebox base around the sides of
the burner assembly and on the tray beneath the grate.
Under no circumstances should this large lava rock
be placed on any part of the burner assembly.

Burner Lava Rock Placement

Place the contents of the small bag of ceramic burner
lava embers on the burner in front of the front logs. Do
not place burner lava rock in the inside corners of the
front logs.

Fig. 65 Flame adjustment knob for SIT valve.

LO

H

I

FP390
FLAME ADJUSTMENT KNOB
11/21/96

Turn

counterclockwise

to increase

flame height

Turn clockwise

to decrease

flame height

SIT 820 Valve

Fig. 64 Flame adjustment knob for Honeywell valve.

LO

HI

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

HV102
Honeywell hi/lo knob
4/5/99 djt

Honeywell Valve

Flame & Temperature Adjustment

For fireplaces equipped with Hi/Lo valves, flame adjust-
ment is accomplished by rotating the Hi/Lo adjustment
knob located near the centre of the gas control. (Fig. 64
or 65)

Manual ON/OFF Valve

The Manual ON/OFF valve was designed particularly
for the main burner operation. The main burner flame
can be turned on and off as desired. This valve is rec-
ommended to be set to the “ON” position when lighting
the unit. (Fig. 66)

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to Fig-
ures 67-68. If any of the flames appear abnormal call a
service person.

F584-703

Honeywell

& PSE

pilot flames

3/8” - 1/2”

(10 - 13 mm)

Fig. 67 Correct pilot flame appearance.

F584-703

SIT Pilot

PSE Pilot

Inspecting the Venting System

This appliance venting system is designed and con-
structed to develop a positive flow adequate to remove
flue gases to the outside atmosphere.
Any foreign objects in the venting system, except those
designed specifically for the venting system, may cause
spillage of flue gases.
To inspect the venting system, make sure the main gas
valve is off. Remove window frame assembly (Refer to
Window Frame Assembly Removal Section). Using a
flashlight, check the area above the baffle in the com-
bustion dome. Clean if necessary.

FP1613

Fig. 66 Manual ON/OFF valve shown on RN/RP models.

Flame Adjustm

en

t

Fa

n

S

pe

ed

Ignitor

ON

OFF PILOT

ON

OFF

ON

OFF

FP1612
Copreci
manual on/off
valve
4/06