10009383

7

XDV Direct Vent Gas Fireplace

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12” (305 mm) or more from
the front of the fireplace.

Cold climate installation recommendation:

When installing this unit against a
non-insulated exterior wall or chase,
it is mandatory that the outer walls
be insulated to conform to applicable
insulation codes.

Hearth

Framing and Finishing

Check fireplace to make sure it is levelled
and properly positioned.

To mount the appliance:
1. Choose the location.
2. This unit comes with four (4) flanges pre-mounted

on both sides of the fireplace to allow two different
drywall thicknesses to be used. Flange “A” is for
1/2” drywall while flange “B” is for 5/8” drywall.

3. Bend the desired flanges out 90° on both sides of

the fireplace. Slide the fireplace into the framed
opening until the flanges contact the front surfaces
of the framing. Level the unit and secure it firmly in
place.

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the fireplace.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the fireplace.

Final Finishing

Fig. 5 Nailing flanges.

Flange

Drywall

Position

Depth

A

1/2” / 13 mm

B

5/8” / 16 mm

Flange Location for

Desired Drywall Depth

A

B

FP1539a
flanges w/standoffs
5/05

FP1539

Max.

Min.

Input

Input

Model

Fuel Gas Control BTU/h BTU/h

33XDVRN

Nat. Millivolt Hi/Lo 21,500 4,400

33XDVRP

Prop. Millivolt Hi/Lo 21,500 5,425

33XDVEN

Nat. 24 Volt Hi/Lo 21,500 4,400

33XDVEP

Prop. 24 Volt Hi/Lo 21,500 5,425

36XDVRN

Nat. Millivolt Hi/Lo 27,500 5,150

36XDVRP

Prop. Millivolt Hi/Lo 27,500 5,500

36XDVRFN Nat. Comfort Contrl 27,500 5,810
36XDVRFP Prop. Comfort Contrl 27,500 6,225
36XDVEN

Nat. 24 Volt Hi/Lo 27,500 5,150

36XDVEP

Prop. 24 Volt Hi/Lo 27,500 5,500

39XDVRN

Nat. Millivolt Hi/Lo 30,000 6,700

39XDVRP

Prop. Millivolt Hi/Lo 30,000 5,800

39XDVEN

Nat

24 Volt Hi/Lo 30,000 6,700

39XDVEP

Prop 24 Volt Hi/Lo 30,000 5,800

Gas Specifications

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the cur-
rent ANSI Z223.1/NFPA 54 and/or local codes hav-
ing jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).

Advertising