Veracity OUTREACH PLUS (Superceded by OUTREACH MAX) User Manual

Installation guide

Advertising
background image

Where to use OUTREACH PLUS

TM

Cables in an Ethernet network are limited in length to 100 metres
(328 feet), however in some installations it is necessary to make a
network connection and deliver high-level Power over Ethernet
(PoE) over distances greater than this.

OUTREACH PLUS solves this problem: it allows high-power PoE,
including IEEE 802.3at (PoE Plus), to be extended with an Ethernet
data connection to up to 200 metres.

In the example above, a single OUTREACH PLUS allows a high-
power networked camera to be installed up to 200 metres (656
feet) away from a network switch. The OUTREACH is connected in-
line after the first 100 metres of cable have been laid, allowing a
further length of up to 100 metres to be installed up to the camera.

As the camera is a PoE Plus device, OUTSOURCE PLUS (VOR-OSP)
should always be used as the PoE source to ensure maximum
range. OUTREACH PLUS draws its own power from the same PoE
source as the powered device (which in this case is the OUTSOURCE
PLUS), so it requires no local electricity supply.

LED indicators

Connector LED

OFF

ON

FLASHING

POE IN

POWER GOOD

no power

power
good

-

LINK / ACTIVITY

no Ethernet
link

Ethernet
link good

network
activity

POE OUT

LINK / ACTIVITY

no Ethernet
link

Ethernet
link good

network
activity

Installation

Quick installation sequence (for PoE Plus):

Install an OUTSOURCE PLUS where power is available, to inject
PoE Plus on the network cable (usually located close to a
network switch port)

Connect the POE IN connector to the OUTSOURCE PLUS

Connect the POE OUT connector to a PoE Plus powered device
(such as a PTZ network camera)

Wait a few seconds for all devices to be enabled

Important notes

OUTREACH PLUS will not power up (no LEDs) until the camera
or other PoE device has been connected.

The OUTSOURCE PLUS injector should always be used for
guaranteed performance in PoE Plus applications. It can be
used to upgrade an existing PoE Plus port if required.

If the powered device is disconnected, its cable will still have a
PoE voltage present on it, which can damage other equipment.
Always disconnect the PoE power source at the same time so
that power is removed from the OUTREACH PLUS.

For conventional PoE (802.3af) or non-PoE applications, the
standard model of OUTREACH (VOR-OR) should always be used.
OUTREACH enables Ethernet extension up to 1000 metres
(3280 feet).

Non-standard PoE

OUTREACH PLUS allows extension of many non-standard PoE
connections. These include:

"Always-on" or "dumb" PoE

Extended-power PoE based on 802.3af

PoE implementations using a non-802.3af signature

OUTREACH PLUS should not be used with "4-pair" PoE or with any
devices that draw greater than the specified maximum power or
current. Maximum range will depend on the PoE implementation
used.

OUTREACH PLUS should only be used with non-standard PoE
implementations that have been approved by Veracity. Please
consult the relevant application notes or enquire with your Veracity
representative before installation.

Technical specification

Power

Typical: 1 Watt, Maximum: 2.2 Watts

POE

Passed through: data/spare pair in, spare pair out
0.8 amp / 30 watt maximum to device

Ethernet

100BASE-TX Full Duplex only
Auto-Negotiation and Auto-Crossover supported

Dimensions
( WxDxH )

75x39x20mm / 3.0x1.6x0.8”
105x42x20mm / 4.2x1.7x 0.8” inc. screws and tabs

Mounting

Two 7mm / 0.28” dia holes, 89mm / 3.5” apart

Weight

110 g / 3.8 oz

Operating temp

-10 to 50°C / 14 to 122°F

Relative humidity Up to 85%, non-condensing

to

powered

dev ice

f rom

power

source

network

cable

network

cable

RJ45

connector

RJ45

connector

EC Declaration of Conformity

In accordance with EN 45014:1998

We, Veracity UK Ltd. of

6 Barns Street, Ayr, KA7 1XA

declare that the equipment

“OUTREACH PLUS” Ethernet repeater

model number

VOR-ORP

conforms to the essential protection requirements of the EMC Directive 89/336/EEC
as amended. The following EMC standards have been applied:

BS EN 55022:1998 Emissions (Class B Radiated)

BS EN 55024:1998 Immunity (BS EN 61000-4-2:1995 Immunity to ESD, BS EN
61000-4-3:2000 Immunity to Radiated RF Fields (3V/m))

I hereby declare that the equipment named above has been been found to comply
with the relevant sections of the above referenced specifications. The unit complies
with all essential requirements of the EMC Directive.

Responsible Person

Mr Alastair McLeod, Director

Issued 14

th

April 2009

at Ayr

This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference
at his own expense.

200m / 660ft

INSTALLATION GUIDE

Advertising