DVBR Series Direct Vent Gas Fireplace

20000584

1. Turn off gas.
2. Let the fireplace cool if it has been operating.
3. Remove valve cover. (Fig.47)
4. Release the two (2) clamps at the bottom of the

window frame by pulling back on the clamp handles.

(Fig. 48)
5. Lift off the glass frame as shown. (Fig. 48)
6. To reinstall glass follow the above procedure in re-

verse.

Glass Information

Only glass approved by CFM Corporation
may be used for replacement.

Glass Frame Removal

Glass Cleaning

Replacement of Ceramic Hearth Panels

1. Remove glass.
2. Remove two (2) hex nuts securing grate to hearth

pan. (Fig. 49)

3. Set left and right panels on hearth and bring towards

front of unit.

4. Replace grate assembly.

It is necessary to clean the glass periodically. During
start-up condensation, which is normal, forms on the
inside of the glass and causes lint, dust and other
airborne particles to cling to the glass surface. Also
initial paint curing may deposit a slight film on the glass.
It is therefore recommended the glass be cleaned

two or three times with a non-ammonia household
cleaner and warm water (gas fireplace glass cleaner
is recommended). After initial use glass should be
cleaned two or three times during heating season.

Clean glass after first two weeks of
operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam the glass.

G584-501

Remove glass frame

2/99 djt

Clamps

Glass Frame

Fireplace
Front

Glass
Panel

Glass
Panel

Pull Clamp
Hook

Fig. 48 Glass panel removal.

G584-501

H100

hearth Panels

3/15/99 djt

Grate

Burner

Hearth Panels

Front of Unit

H100

Fig. 49 Hearth panel location.

Operating Instructions

G584-500

Remove valve cover

2/99 djt

Valve Cover

Valve

Fig. 47 Valve cover location.

G584-500

Pins

Locating Holes

The use of any non-approved replacement glass will
void all product warranties.

Care must be taken to avoid breakage of the glass.

Do not operate appliance with glass front
removed, cracked or broken.

Replacement glass (complete with gasket) is
available through your CFM Corporation dealer
and should only be installed by a licensed
qualified service person.