Troubleshooting – honeywell vs8421 – Vermont Casting DVBR36 User Manual

Page 28

Advertising
background image

28

DVBR Series Direct Vent Gas Fireplace

20000584

Troubleshooting – Honeywell VS8421

START

CHECK

Gas Supply On

Pilot Lights With Piezo
Ignitor

Lockout Has Engaged. Wait 60
Seconds And Try Again.

For Spark At Electrode While
Depressing Piezo

1/8" Gap To Pilot Hood Needed.

All Wiring Connections

Replace Piezo Ignitor

Supply Line Hooked Up

Shutoff Valve Open

PILOT STAYS LIT

For Air In The Lines

Thermopile Needs A Min.
325mv. Adjust Pilot Flame
Height.

All Wiring Connections

Replace Thermopile

Thermocouple Needs A Min. Of
14mv

PILOT LIGHTS MAIN
BURNER

Valve Is Turned On

Wall Switch Is Not Turned On.
Watch For Grounded Wires!

Thermopile Needs A Min. 325mv.

Plugged Burner Orifice

Defective Valve. Turn To Pilot,
Meter Should Read Greater Than
100mv. If Not, Replace.

SYSTEM OK

YES

NO

NO

NO

NO

YES

YES

YES

Remove window frame assembly before service work