Dvbr series direct vent gas fireplace, Flame & temperature adjustment, Flame characteristics – Vermont Casting DVBR36 User Manual

Page 25: Inspecting the venting system

Advertising
background image

25

DVBR Series Direct Vent Gas Fireplace

20000584

�����
���������
����

Right Cover

Log

Center Log

Left Cover Log

LG391

Fig. 52 Place Left and Right Cover Logs and Center Log on grate.

��������
���������
����

Log Top Right

(DVBR42 ONLY)

Left Cross Log

Left Front Log

LG392

Fig. 53 Place Left Front Log, Left Cross Log and Log Top Right.

Top logs must be placed properly onto
notches.

Flame & Temperature Adjustment

For fireplaces equipped with Hi/Lo valves,
flame adjustment is accomplished by rotating
the Hi/Lo adjustment knob located near the
centre of the gas control. (Fig. 54 & 55)

Flame Characteristics

It is important to periodically perform a visual
check of the pilot and the burner flames.
Compare them to Figures 56, 57 & 58. If any
of the flames appear abnormal call a service
person.

Inspecting the Venting System

This appliance venting system was designed
and constructed to develop a positive flow
adequate to remove flue gases to the outside
atmosphere.
Any foreign objects in the venting system,
except those designed specifically for the
venting system, may cause spillage of flue
gases.
To inspect the venting system, make sure the
main gas valve is off. Remove glass frame
(See Glass Frame Removal Section). Using
a flashlight, check the area above the baffle
in the combustion dome. Clean if necessary.

LO

HI

FP390

FLAME ADJUSTMENT KNOB

11/21/96

Turn

counterclockwise

to increase

flame height

Turn clockwise

to decrease

flame height

Fig. 55 flame adjustment knob for SIT valve.

Fig. 54 Flame adjustment knob for Honeywell valve.

��

��

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

HV102

Honeywell hi/lo knob

4/5/99 djt

HV102

3/8” - 1/2”

Fig. 56 Correct pilot flame appearance.

Advertising