Instruction Manual / DE0, DE1 and DE2

Wilkerson Compact Heatless Air Dryers

MODELS DE0, DE1 AND DE2 TROUBLESHOOTING GUIDE

A

PROBLEM: AIR DRYER DELIVERS WET AIR

POSSIBLE CAUSE

CHECK

CORRECTIVE ACTION

A1

High inlet air temperature.

Inlet air temperature should not

Reduce inlet air temperature.

exceed sizing criteria stated
at purchase (usually
70˚F or 100˚F).

A2

Air demand in excess of rated Check downstream flow demand

Reduce air usage downstream.

capacity of air dryer.

with flowmeter.

A3

Low inlet pressure.

Verify actual inlet pressure vs.

Increase inlet pressure or call

nameplate operating pressure.

factory to resize dryer for
inlet conditions.

A4

Dirty or obstructed inlet air

Check filter element.

Replace.

filter.

A5

Purge orifice plugged.

Remove and inspect purge orifice.

Clean hole of debris. Use air
gun to clean.

A6

Solenoid coil burned out.

Check magnetic field from coil

Remove cover, place iron or

operation.

steel material (screwdriver or
nail) on exposed end of solenoid
base to feel the magnetic effect,
indicating proper operation.
(Note: each coil should be
energized for 30 seconds).

A7

Oil contamination of

Verify particle/coalescing inlet

Towers must be replaced if

desiccant beds.

filtration is adequate and

contamination is suspected.

functioning. Inspect inside of
desiccant towers for oily residue.

A8

Timer not operating properly.

Check for proper voltage across

Replace timer if voltage is

L2 and DC1 and across L2 and

present at either DC terminal

DC2. Verify timing cycle is 30

continuously or not at all during

seconds per side. Voltage should

the 1 minute cycle -or- if wrong

read 53 volts DC on a 115 volt AC

voltage is measured.

unit or 106 volts DC on a 230 volt
AC unit.

A9

Purge flow restricted.

Check mufflers for excessive back

Replace mufflers.

pressure.

If purge air is piped away from
unit, oversized piping should be
used and length of run should be
as short as possible.

A10 Desiccant attrition

Remove the desiccant chambers

Install new towers or have

from the air manifold. Check if

towers repacked at the factory.

perforated disc at open end of the
chambers can be depressed more
than 1/4" from the retaining ring.

A11 Solenoid core spring broken.

Remove solenoid valve, inspect

Spring should be seated on core

core assembly.

and not broken. Replace if
necessary.