1.

IMPORTANT! No overload protection is provided in the dryer and unit should be

wired into a protected circuit. A knockout hole is provided for electrical connection.

2. The dryer can be grounded by attaching a ground wire to the timer assembly bracket

screw. See wiring diagram.

G. Solid State Timers – The solid state timers used in the DE series dryers permit the

simultaneous switching of the solenoid valves every 30 seconds. The timers are equipped
with a one hour memory capability. If power is interrupted, the dryer will resume operation
at the same point in the cycle when power is restored.

Wiring Diagram

Figure 4

Instruction Manual / DE0, DE1 and DE2

Wilkerson Compact Heatless Air Dryers

!

Advertising