3. Piping connections: For maximum flow, INLET and OUTLET piping should be schedule 40

pipe or equivalent I.D. tubing. DE0, DE1 and DE2 inlet and outlet porting is 1/4" female
NPT, purge porting is 1/8" female NPT.

NOTE

If purge air is required to be piped to a remote location, it is neces-
sary to use slightly oversized tubing to prevent back-pressure.
Restricting the purge flow can cause the dryer to malfunction.

4. Use Teflon tape or pipe sealant on threads. Check all air connections for leakage, using

soap solution prior to putting dryer into permanent service.

5. It is recommended that a bypass line with shut-off valves be installed to provide constant

air flow, should the dryer require servicing.

6. Always install a 5-micron particulate prefilter and a coalescing filter upstream to remove

entrained particulates, moisture and oil. A 0.5-micron afterfilter should be installed down-
stream to remove any desiccant dust that may migrate from the desiccant towers.

Factory Recommended Dryer Installation

Figure 3

D. Operating Specifications – The DE0, DE1, and DE2 series compact heatless dryers

can be sized to operate from 40 to 150 PSIG (2,7 to 10,3 bar).

1. The dryers must be operated in accordance with the factory sizing charts and original

customer requirements in order to achieve desired dewpoints. Inlet pressure, inlet
temperature, and outlet flow conditions are always specified when purchased.

2. Maximum inlet air temperature is 125°F (52°C).

3. Do not operate dryers in temperatures so low that freezing is a possibility.

E. Electrical Connections – Before wiring, check the dryer nameplate for electrical characteris-

tics. Standard electrical characteristics are 115 Volt, 50/60Hz operation. Models operating on
230 Volt, 50/60Hz operation are available.

Instruction Manual / DE0, DE1 and DE2

Wilkerson Compact Heatless Air Dryers

5-MICRON

PREFILTER

WITH AUTO

DRAIN

MICROALESCER

OPTIONAL

REGULATOR

SHUT-OFF

VALVE

AIR DRYER

WITH MOISTURE

INDICATOR

BYPASS LINE

BYPASS SHUT-OFF VALVE

SHUT-OFF

VALVE

MOISTURE

INDICATOR

0.5-MICRON

POSTFILTER

OPTIONAL

REGULATOR