Wilkerson DE5 User Manual

Page 13

Advertising
background image

Instruction Manual / DE3, DE4 and DE5

Wilkerson Compact Heatless Air Dryers

MODELS DE3, DE4 AND DE5 TROUBLESHOOTING GUIDE

D

PROBLEM: ALARM WILL NOT CLEAR

POSSIBLE CAUSE

CHECK

CORRECTIVE ACTION

D1

Wet air condition not corrected. See Section "A" of

Troubleshooting Guide.

D2

Sensor not dried out.

Allow several minutes for

To speed up alarm clearing,

sensor to dry out after correcting

bleed some air through tire valve

dryer problem. Alarm should clear.

at bottom of sensor housing.
Alarm should clear in less than
than 60 seconds.

D3

Bad humidistat board.

Disconnect humidity cable from

Replace humidistat board.

sensor. Alarm should clear.

Advertising
This manual is related to the following products:

DE4, DE3